Electric Field Calculator

Calculate the electric field strength produced by a point charge at any distance using Coulomb's law.

C
m

Quick Facts

Coulomb's Constant (k)
8.99 x 109
N m2/C2
Elementary Charge
1.602 x 10-19 C
Charge of a proton/electron
Permittivity of Free Space
8.854 x 10-12
F/m (Farads per meter)
Field Direction
Radially outward
For positive charges

Frequently Asked Questions

What is the electric field formula for a point charge?

The electric field formula for a point charge is E = kQ/r2, where E is the electric field strength in N/C, k is Coulomb's constant (8.99 x 109 N m2/C2), Q is the charge in Coulombs, and r is the distance from the charge in meters. This can also be written as E = Q/(4 pi epsilon_0 r2).

Why does electric field follow an inverse-square law?

The electric field follows an inverse-square law because field lines spread out uniformly in all directions from a point charge. As the distance r increases, these lines pass through a sphere of surface area 4 pi r2. Since the total "flux" remains constant but spreads over a larger area, the field strength (flux per unit area) decreases as 1/r2.

What is the difference between electric field and electric force?

Electric field (E) is the force per unit charge at a point in space, measured in N/C. Electric force (F) is the actual force experienced by a specific charge in that field, measured in Newtons. They're related by F = qE, where q is the test charge. The field is a property of the space; the force depends on what charge you place there.

Can electric fields exist in a vacuum?

Yes, electric fields exist in vacuum and actually travel through it most efficiently. The permittivity of free space (epsilon_0) defines how electric fields behave in vacuum. In fact, electromagnetic waves (including light) are oscillating electric and magnetic fields propagating through vacuum at the speed of light.

How do you calculate electric field from multiple charges?

For multiple charges, apply the superposition principle: calculate the electric field vector from each charge separately using E = kQ/r2, then add all vectors. For 2D or 3D problems, break each field into components (Ex, Ey, Ez), sum the components separately, then find the resultant magnitude and direction.

What happens to the electric field inside a conductor?

The electric field inside a conductor in electrostatic equilibrium is zero. Free electrons in the conductor redistribute themselves until they create an internal field that exactly cancels any external field. This is why conductors shield their interiors from external electric fields - the principle behind Faraday cages.

Why are N/C and V/m equivalent units for electric field?

N/C and V/m are equivalent because 1 Volt = 1 Joule/Coulomb, and 1 Joule = 1 Newton-meter. So V/m = (J/C)/m = J/(C m) = (N m)/(C m) = N/C. Both units represent force per charge, with V/m being more common when discussing potential differences and N/C when discussing forces.

How strong is the electric field near everyday objects?

Typical electric field strengths: Earth's surface field is about 100-150 V/m (pointing down), near a Van de Graaff generator about 106 V/m, inside a thundercloud 105-106 V/m (enough to ionize air), and at the Bohr radius of a hydrogen atom about 5 x 1011 V/m.

What is an electric field and how is it calculated?
An electric field is a region of space around an electrically charged object where another charge would experience a force. It describes how a charge influences its surroundings — even before any other charge is placed there. Definition: the electric field E at a point in space is defined as the force per unit positive test charge: E = F / q. Where: E = electric field (V/m or N/C). F = force on the test charge (N). q = the positive test charge (C). Electric field from a point charge (Coulomb's law): E = kQ / r². Where: k = Coulomb's constant = 8.988 × 10⁹ N·m²/C². Q = source charge (C). r = distance from the charge to the point (m). Direction: the field points away from positive charges and toward negative charges. Example calculation: charge Q = +5 μC (5 × 10⁻⁶ C) at distance r = 0.3 m. E = (8.988 × 10⁹ × 5 × 10⁻⁶) / (0.3)² = 44,940 / 0.09 = 499,333 V/m ≈ 499 kV/m. Electric field units: V/m (volts per meter) and N/C (newtons per coulomb) are equivalent: 1 V/m = 1 N/C. Superposition principle: when multiple charges are present, the total field at any point is the vector sum of the individual fields. E_total = E₁ + E₂ + E₃ + ... (vector addition). This means you must account for both magnitude and direction when summing fields from multiple sources. Uniform fields: in a parallel plate capacitor, the field is uniform: E = V/d. Where V = voltage across the plates and d = plate separation in meters.
What is the difference between electric field and electric potential?
Electric field (E) and electric potential (V) both describe the electrical environment around charges, but they are different quantities with different properties. Electric field (E): what it is: force per unit charge at a point. Units: V/m (volts per meter) or N/C (newtons per coulomb). Type: vector — has both magnitude and direction. Interpretation: describes what force a charge would feel at that point. Formula for point charge: E = kQ/r². The field direction points away from positive charges and toward negative charges. Electric potential (V): what it is: potential energy per unit charge. Units: V (volts). Type: scalar — just a number, no direction. Interpretation: describes the potential energy that would be stored per unit charge at that point. Formula for point charge: V = kQ/r. Note: V drops off as 1/r (slower) while E drops off as 1/r² (faster). Relationship between E and V: they are related by: E = −dV/dx (in one dimension). E = −∇V (in three dimensions). The electric field is the negative gradient of the electric potential. This means: the field points from high potential to low potential. Field is strong where potential changes rapidly (steep gradient). Field is zero where potential is constant. Why potential is sometimes easier to use: V is a scalar, so it's easier to add contributions from multiple charges (no vectors). Once V is calculated at all points, E can be found by differentiation. In circuit analysis, we typically work with voltage (potential difference) rather than fields directly. Practical example — parallel plates: potential: V = Ed (voltage = field × distance). Field: E = V/d. If plates are 0.01 m apart and have 100 V between them: E = 100/0.01 = 10,000 V/m (a uniform field between the plates). Potential varies linearly between the plates (0 V to 100 V).
How does distance affect the electric field strength?
For a point charge, the electric field decreases with the square of the distance — an inverse square law, just like gravity. The relationship: E = kQ / r². E is proportional to 1/r². If you double the distance, the field becomes 1/4 as strong (not half). If you triple the distance, the field becomes 1/9 as strong. If you increase distance by a factor of 10, the field becomes 1/100 as strong. Numerical example: charge Q = +1 μC = 10⁻⁶ C, k = 8.988 × 10⁹ N·m²/C². At r = 0.1 m: E = 8.988×10⁹ × 10⁻⁶ / 0.01 = 8.988×10³ / 0.01 = 899,000 V/m. At r = 0.2 m (double): E = 8.988×10³ / 0.04 = 224,700 V/m (¼ of original). At r = 0.3 m (triple): E = 8.988×10³ / 0.09 = 99,867 V/m (1/9 of original). At r = 1.0 m: E = 8,988 V/m (1/100 of original at 0.1 m). Why the inverse square law? The electric force (Coulomb's law) F = kQq/r² also follows the inverse square law. The force spreads out over the surface of a sphere as distance increases. The area of a sphere increases as r². Therefore the force per unit area (and thus the field strength) decreases as 1/r². This is analogous to how light intensity decreases with distance from a point source. Comparison to other field types: gravitational field from a point mass: g = GM/r² (same 1/r² law). Magnetic field from a magnetic dipole: B ∝ 1/r³ (drops off faster). Electric field from an infinite line charge: E = λ/(2πε₀r) — follows 1/r (drops off slower than a point charge). Electric field from an infinite plane: E = σ/(2ε₀) — constant; no distance dependence.
What are the units of electric field?
The electric field has two equivalent unit systems that are both commonly used. Primary units: V/m (volts per meter): comes from the relationship E = V/d (field = voltage / distance). Most common in applied physics, engineering, and everyday contexts. "The electric field is 500 V/m" means a voltage difference of 500 V exists per meter of distance along the field direction. N/C (newtons per coulomb): comes from the definition E = F/q (field = force / charge). Most natural from the fundamental definition of electric field as force per unit charge. "The electric field is 500 N/C" means a 1-coulomb charge would experience a force of 500 newtons. These are equivalent: 1 V/m = 1 N/C. Proof: 1 V = 1 J/C (joule per coulomb). 1 J = 1 N·m. So: 1 V/m = 1 (J/C)/m = 1 (N·m/C)/m = 1 N/C. ✓ Other related units in the SI system: Coulomb's constant k: 8.988 × 10⁹ N·m²/C². Permittivity of free space ε₀: 8.854 × 10⁻¹² C²/(N·m²) or F/m (farads per meter). Electric flux (Φ): V·m (volt-meters) = N·m²/C (from Gauss's law: Φ = Q_enc/ε₀). Larger units used in high-voltage contexts: kV/m (kilovolts per meter) = 1,000 V/m. MV/m (megavolts per meter) = 10⁶ V/m. Common context: the dielectric breakdown of air occurs at approximately 3 MV/m (3,000,000 V/m) — the field strength at which air ionizes and becomes conductive (producing a spark or lightning).

Key Takeaways

  • Electric field strength is calculated using E = kQ/r2 where k = 8.99 x 109 N m2/C2
  • The electric field follows an inverse-square law - doubling the distance reduces field strength by 4x
  • Field direction points away from positive charges and toward negative charges
  • Electric field is measured in Newtons per Coulomb (N/C) or equivalently Volts per meter (V/m)
  • Superposition principle: Total field from multiple charges equals the vector sum of individual fields

What Is an Electric Field? Complete Explanation

Source / Context Electric Field Strength Notes
Earth's atmospheric electric field (fair weather)~100–150 V/mDownward direction; generated by global thunderstorm activity
Earth's atmospheric electric field (near thunderstorm)Up to 10,000–100,000 V/mCauses lightning when breakdown threshold exceeded
Near a high-voltage power line (at ground level)1,000–10,000 V/mRegulated to < 5,000 V/m at edge of right-of-way in US
Dielectric breakdown of air~3,000,000 V/m (3 MV/m)Voltage at which air ionizes and conducts (spark)
Inside a typical capacitor10⁶ – 10⁹ V/mDepends on dielectric material
Near the surface of a conductor (charged)Varies widelyE = σ/ε₀ where σ is surface charge density
Hydrogen atom (electron-nucleus, Bohr radius)~5 × 10¹¹ V/mEnormous field strengths exist at atomic scales
Pulsed electric field (food processing)20,000–80,000 V/mUsed for non-thermal microbial inactivation
Note: Coulomb's law gives the electric field from a point charge: E = kQ/r² = Q/(4πε₀r²). Coulomb's constant k = 8.988 × 10⁹ N·m²/C². The permittivity of free space ε₀ = 8.854 × 10⁻¹² C²/(N·m²).——
Configuration Formula Variables Notes
Point chargeE = kQ/r²k=8.99×10⁹, Q=charge (C), r=distance (m)E field magnitude; direction: away from + charge
Uniform field (parallel plates)E = V/dV=voltage (V), d=plate separation (m)Inside a capacitor or parallel plates
Electric force on chargeF = qEq=test charge (C), E=field (V/m)Force on charge in a field; F = kQq/r²
Electric potential energyU = qV = kQq/rq=charge, V=potential (V), r=distancePE of charge in field
Field from infinite line chargeE = λ/(2πε₀r)λ=linear charge density (C/m), r=distanceCylindrical symmetry; wire or rod
Field from infinite planeE = σ/(2ε₀)σ=surface charge density (C/m²)Uniform; perpendicular to plane; both sides
Note: Superposition principle: the total electric field at any point from multiple charges is the vector sum of individual fields. E_total = E₁ + E₂ + E₃ + ... (vector addition).
Property Electric Field (E) Electric Potential (V) Notes
DefinitionForce per unit chargePotential energy per unit chargeE = F/q; V = U/q
UnitsV/m (volts per meter) or N/CV (volts)V/m = N/C
TypeVector (has direction)Scalar (number only)E has magnitude and direction; V has only magnitude
RelationshipE = −dV/dx (1D)V = −∫E·dxE is the negative gradient of V
From point chargeE = kQ/r²V = kQ/rNote: V ∝ 1/r; E ∝ 1/r²
Zero conditionE = 0 midway between equal opposite chargesV = 0 at infinity (by convention)Different zero conditions
Note: Electric potential (V) is often easier to work with than electric field (E) because V is scalar and E is a vector. Once V is known at all points, E can be found by differentiation: E = −∇V.

An electric field is an invisible region of space around electrically charged particles or objects within which other charged particles experience a force. First described mathematically by Michael Faraday in the 1830s and later formalized by James Clerk Maxwell, electric fields are fundamental to understanding electromagnetic phenomena and form the basis of countless technologies from smartphones to MRI machines.

Unlike magnetic fields which require moving charges, electric fields exist around any stationary charged particle. The field extends infinitely in all directions, though its strength decreases rapidly with distance according to the inverse-square law. When another charged particle enters this field, it experiences a force without any physical contact - this "action at a distance" puzzled physicists for centuries until the field concept provided a satisfying explanation.

The electric field at any point in space represents the force that would be exerted on a positive test charge placed at that location, divided by the magnitude of that test charge. This gives us a measure of field strength that's independent of the test charge we use, making it a fundamental property of space around charged objects.

The Electric Field Formula Explained

E = kQ / r2
E = Electric field strength (N/C)
k = Coulomb's constant (8.99 x 109 N m2/C2)
Q = Source charge (Coulombs)
r = Distance from charge (meters)

This formula, derived from Coulomb's law, tells us several important things about electric fields. The field strength is directly proportional to the source charge Q - a larger charge creates a stronger field. More importantly, the field follows an inverse-square relationship with distance. This means that if you double your distance from a charge, the field strength drops to one-quarter of its original value.

The constant k (Coulomb's constant) can also be written as 1/(4 pi epsilon_0), where epsilon_0 is the permittivity of free space. In materials other than vacuum, the permittivity changes, affecting the electric field strength. This is why electric fields behave differently in conductors, insulators, and different dielectric materials.

How to Calculate Electric Field (Step-by-Step)

1

Identify the Source Charge

Determine the magnitude of the charge creating the electric field. Convert to Coulombs if necessary. Example: A proton has charge +1.602 x 10-19 C.

2

Measure the Distance

Find the distance from the charge to the point where you want to calculate the field. Convert to meters. Example: 5 cm = 0.05 m.

3

Apply the Formula

Substitute values into E = kQ/r2. Use k = 8.99 x 109 N m2/C2.

4

Calculate and Express Result

Perform the calculation and express in N/C or V/m with appropriate significant figures. Use scientific notation for very large or small values.

5

Determine Direction

The field points radially outward from positive charges and radially inward toward negative charges. Draw a vector diagram if needed.

Practical Electric Field Examples

Example 1: Electric Field from a Point Charge

Calculate the electric field 10 cm from a charge of 2 microCoulombs (2 x 10-6 C).

Charge (Q) 2 x 10-6 C
Distance (r) 0.1 m
Electric Field (E) 1.80 x 106 N/C

E = (8.99 x 109)(2 x 10-6) / (0.1)2 = 1.80 x 106 N/C

Example 2: Field at Different Distances

How does the field change when distance doubles from 5 cm to 10 cm? (Q = 1 microCoulomb)

At 5 cm 3.60 x 106 N/C
At 10 cm 8.99 x 105 N/C
Ratio 4:1 (inverse square)

Doubling the distance reduces the field strength to exactly 1/4 - demonstrating the inverse-square law.

Example 3: Electric Field of an Electron

Calculate the electric field at the Bohr radius (5.29 x 10-11 m) from an electron.

Electron Charge 1.60 x 10-19 C
Bohr Radius 5.29 x 10-11 m
Electric Field 5.14 x 1011 N/C

This enormous field strength at atomic scales explains why electromagnetic forces dominate atomic structure.

Common Mistakes When Calculating Electric Fields

Avoid These Common Errors

  • Forgetting to square the distance: The most common error - E is inversely proportional to r2, not r.
  • Unit conversion errors: Always convert to SI units (Coulombs, meters) before calculating.
  • Confusing E with F: Electric field (E) is force per unit charge, not the force itself. F = qE.
  • Ignoring direction: Electric fields are vectors - magnitude alone is incomplete.
  • Wrong sign interpretation: Negative charges create fields that point inward, positive outward.
  • Using wrong constant: Use k = 8.99 x 109, not 9.0 x 109 for precision work.

Pro Tips for Electric Field Calculations

Pro Tip: Converting Between N/C and V/m

The units N/C (Newtons per Coulomb) and V/m (Volts per meter) are exactly equivalent for electric field. Use whichever is more convenient for your application. V/m is often preferred when working with voltage and potential differences.

Pro Tip: Quick Estimation Using Powers of 10

For quick estimates, remember that k is about 9 x 109. This makes mental math easier: a 1 C charge at 1 m creates a field of about 9 x 109 N/C. Scale from there using the inverse-square relationship.

Pro Tip: Superposition for Multiple Charges

When calculating fields from multiple charges, calculate each field vector separately, then add them using vector addition. For charges on the same line, add or subtract magnitudes based on direction.

Real-World Applications of Electric Fields

Understanding electric fields is crucial across numerous technologies and scientific disciplines:

  • Capacitors and electronics: Electric fields store energy in capacitors, forming the basis of energy storage in circuits.
  • Particle accelerators: Electric fields accelerate charged particles to near light speed in facilities like CERN.
  • Electrostatic precipitators: Use electric fields to remove particulate matter from industrial exhaust.
  • Xerography (photocopying): Electric fields control toner placement in laser printers and copiers.
  • Medical imaging: MRI machines use electric and magnetic field interactions for imaging.
  • Atmospheric science: Electric fields in thunderclouds drive lightning formation.
  • Semiconductor devices: Transistors operate by controlling electric fields in silicon.
What significant figures should I use?
Match your significant figures to your least precise input. If you measured a length to 3 sig figs, report your answer to 3 sig figs regardless of how many decimal places the calculator shows. Excess decimal places imply false precision and are misleading in scientific reporting.