Well Pressure Tank Drawdown Planner

Estimate usable drawdown and theoretical tank size for a private-well system. Use your pump’s net fill rate and the minimum run time specified for your equipment.

Enter your pressure-system settings

Estimate pump flow minus water being used while it runs.
Enter the target from your pump or motor maker or installer.
Use the nominal capacity printed on the tank; enter 0 if unknown.

How pressure-tank drawdown is estimated

A pre-pressurized well tank holds less usable water than its nominal gallon capacity. Drawdown is the water delivered between the pressure switch’s cut-out and cut-in points. This planner uses an ideal-gas estimate from gauge pressures converted to absolute pressure (adding atmospheric pressure, approximately 14.7 PSI at sea level).

Formula used

Estimated drawdown fraction = P₀ × (P₂ − P₁) ÷ (P₁ × P₂), where P₀ is absolute air precharge, P₁ is absolute cut-in pressure, and P₂ is absolute cut-out pressure. Estimated usable tank drawdown = nominal tank gallons × drawdown fraction. Required drawdown = net fill flow (GPM) × target pump run time (minutes). The theoretical nominal capacity is required drawdown divided by the estimated fraction.

Use the tank maker’s data for selection

Bladder and diaphragm design, tank geometry, operating limits, and testing methods can make actual drawdown differ from this ideal-gas estimate. Manufacturer model data takes precedence for selecting a tank. For example, Amtrol’s well-tank support says its precharge should be set 2 PSI below pressure-switch cut-in; verify the procedure for your own equipment. This planner accepts your measured settings rather than assuming that adjustment.

What net fill flow means

Use the net flow available to refill the tank while the pump is operating: pump output minus concurrent household demand. If the net value is uncertain, have a qualified well professional measure system performance. The result is a theoretical planning estimate, not a substitute for pump-maker guidance, tank specifications, electrical checks, or local plumbing requirements.

Frequently asked questions

Is nominal tank capacity the same as drawdown?

No. Only a portion of the tank’s nominal water volume is usable between switch pressures. The percentage depends on precharge and operating pressures.

Why enter the precharge separately?

Actual precharge may not match a factory setting or rule of thumb. Measure and adjust only as directed by the exact tank manufacturer, with the water side depressurized when required.

Should I increase the calculated tank size by a safety margin?

Use published tank drawdown data and the equipment maker’s minimum run-time guidance. This tool does not add a generic margin because system and product requirements vary.